CITY – GATES DROP TEST
All fire doors are required to be drop tested annually VISUAL INSPECTION Conduct a visual inspection for anything that may cause a hazard during testing
Retrofit fire door operators provide state-of-the-art technology for existing rolling fire doors. When retrofitted, even older doors can be tested and reset easily, and operate with the reliability and extraordinary descent control found only in the most advanced fire door systems available today. Retrofit operators are Underwriters Laboratories (UL) Classified and FM Approved for installation on most types and brands of existing rolling fire doors. They eliminate awkward and unreliable spring tension release mechanisms and replace traditional operating and governor systems. They may also be installed to replace similar type failsafe operating systems. All retrofit fire door operators feature an internal release and governor to provide automatic closing without a loss of spring tension and eliminate the need for traditional mechanical reset.
EZ Reset Chain, Crank and Motor Operators
Fusible link activated closing through the operator´s internal release and governor.To reset, reconnect the fusible link cable and open the door.
EZ Reset Plus Chain, Crank and Motor Operators
Time delayed closing upon alarm/detector activation, and failsafe closing upon a loss of power, through the operator´s internal release and governor. To reset, clear the alarm, restore power, reconnect the fusible link cable, and open the door.
Auto Reset Chain, Crank and Motor Operators
Time delayed closing upon alarm/detector activation, and failsafe closing upon a loss of power, through the operator´s internal release and governor. To reset, clear the alarm, restore power, and open the door.
Auto Reset Plus Motor Operators
Motor controlled closing upon alarm/detector activation-will stop upon sensing an obstruction while closing and continue closed when the obstruction is removed. (Requires the door to be provided with a monitored sensing edge – power must be present and sensing edge must be functioning properly.) Time delayed failsafe closing through the operator´s internal release and governor upon a loss of power, or failure of the sensing edge upon alarm activated motor controlled closing. Optional battery back-up to provide up to 8 hours battery support to prevent door closing due to a loss of power, obstruction sensing & cycling functions upon alarm/detector activation, and audible/visible warnings. If required, fusible link activated closing through the operator´s internal release and governor. To reset, clear the alarm/restore power, and activate the open control.
All fire doors are required to be drop tested annually VISUAL INSPECTION Conduct a visual inspection for anything that may cause a hazard during testing
Shutters for parts windows, ticket counters or distribution windows SPECIFICATIONS Counter Fire Shutters are designed specifically for pass-thru openings requiring fire protection. These units, with
Rolling Steel Doors for Healthcare facilities and where fire separation is needed Product Description U. L. Labeled Fire Doors are rated closures for fire protection
Auto Reset Motors allow for easy drop testing when required Product Description Retrofit fire door operators provide state-of-the-art technology for existing rolling fire doors. When